MP1 USER INSTRUCTIONS ENGLISH 26999958

– 10-12

Page 21 of 48

flowserve.com

or

constant level oiler bottle or the level mentioned on

sectional drawing.

When fitted with a constant level oiler, the bearing
housing should be filled by unscrewing or hinging back
the transparent bottle and filling the bottle with oil.
Where an adjustable body Trico oiler is fitted this
should be set to the proper height.

The oil filled bottle should then be refitted so as to
return it to the upright position. Filling should be
repeated until oil remains visible within the bottle.

Other drivers and gearboxes, if appropriate, should be
lubricated in accordance with their manuals.

In case of separate shaft mounted lube oil circulating
pump, refer to general arrangement drawing for
instructions

5.2 Lubricants


5.2.1 Typical oils


Table 4

– Typical lubricating oils

Company

Column “A”

Column “B”

Column “C”

Mobil

Mobil DTE Oil BB

MOBILGEAR 626

Mobil DTE Oil HH

Shell

OMALA Oil 220

OMALA Oil 68

OMALA Oil 460

Sunoco

SUNVIS 790 (220)

SUNVIS 747 (46)

SUNVIS 7150

Amoco

RYKON Oil No. 220

AMOGEAR No. 68

American Industrial Oil No. 460

Texaco

REGAL R&O 220

MEROPA 150

REGAL R&O 460

Arco

PENNANT NL 220

PENNANT NL 68

RUBILENE 460

Chevron

AW Machine Oil 220

EP Industrial Oil 46x

NL Gear Compound 460

Exxon

TERESSTIC N220

SPARTAN EP 68

TERESSTIC 460

*Esso

TERESSO N220

SPARTAN EP 68

CYLESSO TK 460

TERESSO 100

-

-

BP

ENERGOL HL 100

-

-

Petro Canada

GIREX 220

GIREX 68

GIREX 320

*Imperial Oil Limited (Canada)

5.2.2 Lubrication schedule

5.2.2.1 Requirements for oil lubricated bearings
Normal oil change intervals are 2500 operating hours or
at least every 6 months whichever occurs first,
depending on the temperature of the service, the
service conditions, and quality of the lubricant regarding
oxidation stability capability. For pumps on hot service
or in severely damp or corrosive atmosphere, the oil will
require changing more frequently. Lubricant analysis
(change in appearance, odour, viscosity, oxidation,
water/contaminants concentration, etc.), as well as
bearing temperature analysis, can be useful in
optimizing lubricant change intervals.

The lubricating oil should be a high quality mineral oil
having foam inhibitors. Synthetic oils may also be used
if checks show that the rubber oil seals will not be
adversely affected.

The bearing temperature may be allowed to rise to
50 ºC (90 ºF) above ambient, but should not exceed
82 ºC (180 ºF). An abrupt or continuously rising
temperature may be indicating a fault.


Oils used in the bearing housing should meet the
following requirements:

1. Oxidation Stability Specification per AGMA

Standard 250.04 table 1, page 9.

2. Foam Suppression Specification per AGMA

Standard 250.04 table 1, page 9.


At initial start-up, oil must be drained completely and
replaced after one week or 100 hours running time
(except for temperatures above 121

C (250

F)), or

even earlier, after 50 hours running time.

An analysis of the expected operating temperatures
should be conducted to determine the proper oil that
should be used in the pump. It should be noted in the
case of a large swing in ambient temperatures, it may
require different types of oils are used for summer and
winter. Unless otherwise noted by Flowserve
engineering, the following information should be used
to determine the proper oil to use in the pump and
whether more than one type of oil may be required
during yearly operation.