Certification, Other relevant documentation and manuals, 1 supplementary user instruction manuals – Flowserve MP1 Sier-Bath User Manual

Page 44: 2 change notes, 3 additional sources of information, Optional, Equipment, Arrangements, 1 jacketed components

Advertising
background image

MP1 USER INSTRUCTIONS ENGLISH 26999958

– 10-12

Page 44 of 48

flowserve.com

9

CERTIFICATION


Certificates,

determined

from

the

contract

requirements will be provided with this manual.
Examples are certificates for CE marking and ATEX
marking. If required, copies of other certificates sent
separately to the Purchaser should be obtained from
Purchaser for retention with the User Instructions.

10 OTHER RELEVANT DOCUMENTATION

AND MANUALS

10.1 Supplementary User Instruction
manuals


S

upplementary instruction determined from the

contract requirements for inclusion into User
Instructions such as for a driver, instrumentation,
controller, sub-driver, seals, sealant system, mounting
component, etc., are included under this section. If
further copies of these are required they should be
obtained from the purchaser for retention with these
User Instructions.

Where any pre-printed set of User Instructions are
used, and satisfactory quality can be maintained only
by avoiding copying these, they are included at the
end of these User Instructions such as within a
standard clear polymer software protection envelope.

10.2 Change notes


If any changes, agreed with Flowserve Pump Division,
are made to the product after its supply, a record of
the details should be maintained with these User
Instructions.

10.3 Additional sources of information


Reference 1:
API Std 676, Positive Displacement Pumps – Rotary,
Third Edition, 2009

Reference 2:
Pumping Manual, 9

th

edition, T.C. Dickenson, Elsevier

Advanced Technology, United Kingdom, 1995.

Reference 3:
Pump Handbook, 2

nd

edition, Igor J. Karassik et al,

McGraw-Hill Inc., New York, 1993.

Reference 4:
ANSI/HI 1.1-1.5

Centrifugal Pumps - Nomenclature, Definitions,
Application and Operation.

Reference 5:
ANSI B31.3 - Process Piping.

11 OPTIONAL

EQUIPMENT

AND

ARRANGEMENTS

11.1 Jacketed components.


For pumps equipped with jacketed bodies and/or
stuffing boxes, the maximum allowable jacketed
pressure is 8.6 bar (125 PSIG] for steam or other
gaseous heat transfer media and 10.3 bar (150 PSIG]
for liquid heat transfer media (Dowtherm, Therminol]
unless otherwise specified on contract drawings. On
jacketed bodies, using steam, the inlet connection
should be at the highest connection on the body with
the outlet at the lowest connection on the opposite end
and side. This should be reversed when using a liquid
heat transfer medium. It is the user's responsibility to
ensure the normal steam temperature does not
exceed the defined maximum permitted value for the
particular Temperature Class.

There are two styles of jacket available, the integral
type and the bolt on type. The integral type need only
be connected as described whereas the bolt on type
must be installed per instructions using the heat
transfer cement supplied. Failure to do this will result
in uneven heat distribution within the pump and may
lead to premature failure.