Flowserve WUC Worthington User Manual

Page 10

Advertising
background image

WUC USER INSTRUCTIONS ENGLISH - 07/14

Page 10 of 52

dB(A) Value

63

125

250

500

1 K

2 K

4 K

8 K

57

48

52

52

50

50

50

48

43

59

50

54

54

52

52

52

50

45

61

52

56

56

54

54

54

52

47

63

54

58

58

56

56

56

54

49

70

60

64

64

62

62

62

60

55

64

54

58

58

56

56

56

54

49

72

62

66

66

64

64

64

62

57

64

54

58

58

56

56

56

54

49

72

62

66

66

64

64

64

62

57

66

56

60

60

58

58

58

56

51

74

64

68

68

66

66

66

64

59

67

57

61

61

59

59

59

57

52

73

63

67

67

65

65

65

63

58

68

58

62

62

60

60

60

58

53

69

59

63

63

61

61

61

59

54

74

64

68

68

66

66

66

64

59

69

59

63

63

61

61

61

59

54

70

60

64

64

62

62

62

60

55

70

60

64

64

62

62

62

60

55

71

61

65

65

63

63

63

61

56

71

61

65

65

63

63

63

61

56

72

62

66

66

64

64

64

62

57

73

63

67

67

65

65

65

63

59

74

64

68

68

66

66

66

64

60

Sound pressure readings are for information only and are not subject to guarantee by Flowserve/IDP.

Decibel readings do not include driver or system noise.

Pum p tested at 100% of the best efficiency point at max.impeller diameter with water.

dB correction for combining noises (pump+motor)

Add to the higher level to obtain
the combined noise level,dB

Note :

1) The values showed are measured at a distance of 1 mt. (horizontally) from major pump

surfaces and 1.5 mt. above the floor.

2) The values shown are expressed in dB (A)

3) For Noise Test Procedure refer to Works Standard L-109

4) The values shown have been derived from actual noise-test data and are based on the following conditions:

- Equipm ent is located in a free field above a reflecting plane in which the reductionin noise level

in all directions is 6db in each octave band for each doubling of distance.

- Background noise is 10dB minimum below all noise levels in each octave band.
- The values shown are at a distance of 1 meter (horizontally) from the major pump surface and

1,5 meters above the floor, using a standard pressure reference of 0,00002 newton per square meter.

- Overall noise level, dB(A) is determ ined at points of m aximum noise level and the values of all

mid-band frequences are basis A scale readings.

When the required condition flow is outside the range of 75 to 125% BEP, a part load correction (PLC) must be

added to the noise level as follows:

Percent of BEP @

required impeller

diameter

PLC in

dB

74 to 62 or 126 to 136

+1

61 to 50 or 137 to 150

+2

49 to 38

+3

37 to 25

+4

1500 rpm

1800 rpm

Motorstand 0

1450 rpm

Motorstand 8

Motorstand 7

1500 rpm

1800 rpm

1800 rpm

Motorstand 6

1500 rpm

1800 rpm

3000 rpm

1500 rpm

1800 rpm

Motorstand 4

Motorstand 1

3000 rpm

1500 rpm

3600 rpm

1800 rpm

Motorstand 3

3000 rpm

1500 rpm

1

0.5

0

3

2.5

2

1.5

6

9

10

3600 rpm

levels to be com bined, dB

Difference between two

3000 rpm

1500 rpm

Motorstand 5

1800 rpm

0

1

2

4

1760 rpm

2900 rpm

3600 rpm

Octave MID BAND frequency [Hz]

Advertising
This manual is related to the following products: