2 nomenclature – Flowserve FP User Manual

Page 13

Advertising
background image

FP USER INSTRUCTIONS ENGLISH 71576286 - 02/13

Page 13 of 40

The pump must be stored in a non-explosive,

ventilated location, sheltered from bad weather, dust
and vibrations.

Maximum working pressure at discharge
................................................................ 25 bars

Maximum working pressure at suction .... 16 bars
except 122-152 and 202 FP .................... 10 bars

Maximum pumped fluid temperature ...... 105 °C
impeller and diffuser for

CAST IRON

or

BRONZE

.

Minimum pumped fluid temperature ....... -10 °C

Maximum ambient temperature .............. 40 °C

Maximum solid suspension ..................... 50 g/m

3

Density........................................................... 1

Viscosity .............................................. 1 mm²/s

Frequency ................. 50 Hz (1450 - 2900 min

-1

)

................................... 60 Hz (1750 - 3500 min

-1

)

Maximum number of stages (according to
rotation speed)

3500

min

-1

2900

min

-1

1750

min

-1

1450

min

-1

50 FP

6

7

7

7

65 FP

4

6

7

7

80 FP

3

5

6

6

100 FP

3

5

6

6

122 FP

4

5

125 FP

2

3

4

5

152 FP & 202

FP

3

4

The maximum speed is shown on the

pump nameplate.


3.2 Nomenclature


Characteristics shown on the nameplate fixed on the pump are as shown below:

Each pump is supplied with the following nameplate:
















Each pump unit is supplied with the following nameplate:



Mass of the set




EU Regulation 547/2012 requires the statement on a product nameplate:

MEI

0.10 [--.-] (Between 1st January 2013 and 1st January 2015)

MEI

0.40 [--.-] (From 1st January 2015)

Pump type

Speed of rotation

Flow rate

Year of construction +

Manufacture number

Head

Radial/thrust bearing

Mass

Maximum admissible
Pressure at 20 °C

Maximum / minimum
temperature