Flowserve FP User Manual

Page 25

Advertising
background image

FP USER INSTRUCTIONS ENGLISH 71576286 - 02/13

Page 25 of 40

6.2.5 Gland packing

6.2.5.1 Pump fitted with a packed gland
A well run in and correctly adjusted packing gland
requires little maintenance.
If, after some time, the leakage becomes too great,
the gland should be tightened again in order to
return these to a normal level.

If re-tightening is not possible, new packing must be
installed

6.2.5.2 Gland packing inspection and removal
a) Remove the shield guards.
b) Slide back the gland.
c) Remove the packing rings with an extractor

designed for this purpose (including the lantern
ring if it exists; note its position and its direction
of rotation).

d) Inspect the state of the sleeve surface; the

presence of many marked grooves will indicate
that it must be replaced.

e) Carefully clean the different pieces of the

packing gland.


6.2.5.3 Gland packing fitting
If the packing is supplied as cord the packing must
be cut so that the external diameter is lightly
tightened and there is an initial gap between the
sleeve and the packing ring.

For that purpose, wind the packing helically around
the shaft sleeve or a chuck of the same diameter.
(Take precautions to avoid damaging sleeve)

Example of straight

Example of bevel cut

Ensure a tightening on the stuffing

box housing and not on the sleeve.

SETTING OF PACKING


Follow the instructions:
a) Assemble of the packing in S.
b) Stagger by about 90° between two rings.
c) Assemble packing after packing.


After setting the last packing ring, secure the
packing with the gland and tighten the nut by hand.
After tightening, the shaft should turn by hand as
easily as before the setting of the packing.

PUMP

TYPE

DIMENSIONS IN MILLIMETERS

PACKING

D1

D2

D3

D4

D5

L1

Lgth

50 FP

24

30

46

70

M10

48

600

8

65 FP

24

30

46

70

M10

48

600

8

80 FP

32

40

60

86

M12

63

800

10

100 FP

32

40

60

86

M12

63

800

10

122 FP

45

55

75

100 M12

45

850

10

125 FP

40

50

70

96

M12

60

1000

10

152 FP

55

70

95

135 M12

78

1100

12

202 FP

65

80

109

150 M16

91

1200

14


For arrangement of packing, see section 8.1,
Sectional drawings.

Advertising