3 grouting, 4 initial alignment – Flowserve FP User Manual

Page 15

Advertising
background image

FP USER INSTRUCTIONS ENGLISH 71576286 - 02/13

Page 15 of 40

4.3 Grouting


4.3.1 Base plate grouting
a) Prepare the site for grouting. Before grouting

clean the foundation surface thoroughly and
provide external barriers as shown:

Barriers

b) Prepare grouting product (concrete, resin) in

accordance with manufacturers' instructions.

c) Use grouting products with anti-shrinking

components.

d) To grout up to the required level. Polish

surfaces. Take necessary precautions to avoid
air bubbles.

e) Lay-down the barrier, break external angles, and

polish the different surfaces.

f) After grout starts to cure, definitively tighten

anchor bolts.

g) Control the alignment such as described as

follows.

4.4 Initial alignment

Before connecting the couplings

verify the motor rotation direction.

4.4.1 Thermal expansion

The pump and motor will normally

have to be aligned at ambient temperature and
should be corrected to allow for thermal expansion
at operating temperature. In pump installations
involving high liquid temperatures, the unit should be
run at the actual operating temperature, shut down
and the alignment checked immediately.

4.4.2 Alignment methods

Ensure pump and driver are isolated

electrically and the half couplings are disconnected.
Ensure that the pump pipework, suction and
discharge, is disconnected.

The alignment MUST be checked.


Although the pump will have been aligned at the
factory it is most likely that this alignment will have
been disturbed during transportation or handling. If
necessary, align the motor to the pump, not the
pump to the motor.

Alignment
Parallelism and concentricity check:

Check the alignment at three or four

points, before pipeworks assembly.

with a rule

with a comparator


Admissible margin for a motor with roller bearings:
= 0.15 mm parallel checking
= 0.1 mm angular checking

Angular checking:

with a sliding rule

with a caliper gauge

The alignment will be definitive only

after pipework connection (see § 4.5.1).