6.2.6 Internal coating
If the pump has an internal coating, this coating
must be inspected periodically. Any wear or cracks
of the coating found must be immediately repaired.

Failure to do this may lead to accelerated wear of
the coating during operation and corrosion of the
exposed base metal, depending on the material and
pumped liquid. Special attention must be paid to the
coating edges.

Any loss of coating material is considered to be
normal wear and tear on the pump and is not
considered as warranty.

Flowserve has applied the coatings according to the
supplier's instructions but will not be held
responsible for coating wear or cracks that may
develop over time.

6.3 Spare parts


6.3.1 Ordering of spares
Flowserve
keeps records of all pumps that have
been supplied. When ordering spares the following
information should be quoted:

1) Pump serial number.
2) Pump size.
3) Part name
4) Part number
5) Number of parts required.


The pump size and serial number are shown on the
pump nameplate.

To ensure continued satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve. Any change to
the original design specification (modification or use
of a non-standard part) will invalidate the pump’s
safety certification.

6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.

6.4 Recommended spares and
consumable items


50 FP, 65 FP, 80 FP, 100 FP, 125 FP
: [2250] -
[3011-01] - [3011-02] - [4130] - [4590] - [4610]

122 FP, 152 FP, 202 FP: [2250] - [3011-01] - [3011-
02] - [4130] - [4590-01] - [4590-02] - [4610-01] -
[4610-02] - [4610-03] - [4610-04]

a) Destroy all the gaskets after dismantling, replace

them when reassembling.

b)

IT IS RECOMMENDED THAT

BEARINGS ARE NOT REUSED AFTER ANY
REMOVAL FROM THE SHAFT.


c) After serving during two years, replace the gland

packing.

6.5 Disassembly

Refer to section 1.6,

Safety, and section 6

Maintenance, before dismantling the pump.

Before dismantling the pump for

overhaul, ensure genuine Flowserve replacement
parts are available. Refer to sectional drawings for
part numbers and identification.

REPAIR OF THE PUMP

If the pump presents abnormalities or a

persistent malfunction, contact immediately:

FLOWSERVE

After-sales Service

Tel.: 02 43 40 57 57

(33) 2 43 40 57 57

Fax.: 02 43 40 58 17

(33) 2 43 40 58 17

Advertising