Polybase Baseplate INSTRUCTIONS ENGLISH 71569284 – 12-10

Page 5 of 24

flowserve.com

1.6.4

Products used in potentially explosive
atmospheres

Measures are required to:

Avoid excess temperature

Prevent build up of explosive mixtures

Prevent the generation of sparks

Prevent leakages

Maintain the pump to avoid hazard


The following instructions for pumps and pump units
when installed in potentially explosive atmospheres
must be followed to help ensure explosion protection.
For ATEX, both electrical and non-electrical equipment
must meet the requirements of European Directive
94/9/EC. Always observe the regional legal Ex
requirements eg Ex electrical items outside the EU may
be required certified to other than ATEX eg IECEx,
UL/CSA.

1.6.4.1

Scope of compliance

Use equipment only in the zone for which it is

appropriate. Always check that the driver, drive
coupling assembly, seal and pump equipment are
suitably rated and/or certified for the classification of the
specific atmosphere in which they are to be installed.

Where Flowserve has supplied only the bare shaft
pump, the Ex rating applies only to the pump. The party
responsible for assembling the pump set shall select the
coupling, driver and any additional equipment, with the
necessary CE Certificate/ Declaration of Conformity
establishing it is suitable for the area in which it is to be
installed. That party are also responsible for CE
Marking the complete machine.

The output from a variable frequency drive (VFD) can
cause additional heating effects in the motor and so,
for pumps sets with a VFD, the ATEX Certification for
the motor must state that it is covers the situation
where electrical supply is from the VFD. This
particular requirement still applies even if the VFD is
in a safe area.

1.6.4.2

Marking

An example of ATEX equipment marking is shown
below. The actual classification of the pump will be
engraved on the nameplate.

II 2 GD c IIC T135 ºC (T4)

Equipment Group
I = Mining
II = Non-mining

Category
2 or M2 = high level protection
3 = normal level of protection

Gas and/or dust
G = Gas
D = Dust

c = Constructional safety

(in accordance with EN13463-5)

Gas Group
IIA – Propane (typical)
IIB – Ethylene (typical)
IIC – Hydrogen (typical)

Maximum surface temperature (Temperature Class)
(see section 1.6.4.3.)

1.6.4.3

Avoiding excessive surface
temperatures

ENSURE THE EQUIPMENT TEMPERATURE

CLASS IS SUITABLE FOR THE HAZARD ZONE

1.6.4.4

Preventing sparks

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking.

To avoid the potential hazard from random induced
current generating a spark, the earth contact on the
baseplate must be used.

Avoid electrostatic charge: do not rub non-metallic

surfaces with a dry cloth

;

ensure cloth is damp.


The coupling must be selected to comply with 94/9/EC
and correct alignment must be maintained.

Additional requirement for metallic pumps on
non-metallic baseplates

When metallic components are fitted on a non-
metallic baseplate they must be individually earthed.