overstress these components, e.g. the max permitted tightening
torque must not be exceeded.

6.8 Assemble the equipment per manufacturer specifications. Avoid

pipe strain. Align the coupling per manufacturer specifications.

6.9 With the impeller, shaft, coupling and bearings in their final oper-

ating position, tighten the drive collar set screws. See Figure .

Recommended ISC2 seal minimum set screw torque by size range:
Seal

inch 1.000 - 2.500 2.625 - 2.750

2.875 - 8.000

2.875 - 8.000

Size

(mm)

(25 - 60)

(67 - 70)

(75 - 203)

(75 - 203)

Gland Size

All

All

Standard Bore

Enlarged Bore

Torque

0 in-lbs

120 in-lbs

150 in-lbs

20 in-lbs

(.5 N-m)

(13.5 N-m)

(16.9 N-m)

(27.1 N-m)

Inaccurate tightening of these screws can lead to unsafe situa-
tion as mechanical seal may move out of the seal chamber when
pressure is applied.

Figure 5