Flowserve ISC2 Series User Manual
Page 13

flowserve.com
13
overstress these components, e.g. the max permitted tightening
torque must not be exceeded.
6.8 Assemble the equipment per manufacturer specifications. Avoid
pipe strain. Align the coupling per manufacturer specifications.
6.9 With the impeller, shaft, coupling and bearings in their final oper-
ating position, tighten the drive collar set screws. See Figure .
Recommended ISC2 seal minimum set screw torque by size range:
Seal
inch 1.000 - 2.500 2.625 - 2.750
2.875 - 8.000
2.875 - 8.000
Size
(mm)
(25 - 60)
(67 - 70)
(75 - 203)
(75 - 203)
Gland Size
All
All
Standard Bore
Enlarged Bore
Torque
0 in-lbs
120 in-lbs
150 in-lbs
20 in-lbs
(.5 N-m)
(13.5 N-m)
(16.9 N-m)
(27.1 N-m)
Inaccurate tightening of these screws can lead to unsafe situa-
tion as mechanical seal may move out of the seal chamber when
pressure is applied.
Figure 5
Figure 4