1 disassemble and clean, 2 ongoing inspection – Flowserve PSS III Durametallic User Manual

Page 4

Advertising
background image

4

1 Disassemble and Clean

1.1 Remove the cap screws from the seal drive and gland.
1.2 Remove the rotating and stationary face halves by lifting the

center of each face up above their drive or lock pins and sliding

the face away from the seal drive or gland.

1.3 Remove the spring holder by pulling out the lock pins. See Figure 2.

1.4 Soak the parts in a solvent

to remove the secondary

seals, cap screw retainers and

retaining sleeves, adhesive,

grease, etc. Suggested solvents

include:

• Loctite X-NMS 768

• Acetone

• Trichloroethane (chlorothene)

Note: Follow all Material Safety Data

Sheet (MSDS) recommendations when handling these fluids.

1.5 Remove any remaining adhesive by brushing or lightly scraping.
1.6 Wash parts in hot soapy water. Rinse thoroughly in clean water.

Let parts dry.

Caution: Do not sand or bead blast gasket and joint surfaces in the

seal drive and gland to avoid damaging them. Glue, rubber, or

heavy deposits must be carefully scraped off these surfaces

before installing the gaskets.

2 Ongoing Inspection

During the assembly process follow these inspection procedures to avoid

errors which may not be correctable later.
2.1 Check Adhesion - Gently tug at the gaskets to be sure they are

properly secured. If they come loose easily, it is likely that the

surfaces were not adequately cleaned or rinsed. Clean the surface

again and reapply adhesive per the instructions. Apply small dots

of adhesive only where specified. Dot size should be 1.00 to

2.00 mm (0.040 to 0.080 inch) in diameter.

2.2 Gasket Length - Be sure that the rotating face gasket, stationary

face seat gasket, and seal drive sleeve gasket are 0.65 to 0.90 mm

(0.025 to 0.035 inch) longer than the surfaces where they end.

See Figure 3. If they are not, reposition them accordingly.

Figure 2