Flowserve PSS III Durametallic User Manual

Page 7

Advertising
background image

7

Figure 9

Figure 10

since too much adhesive impedes

gasket flexibility and can lead to

excessive leakage.

4.6 Push the end into the adhesive

and check the gasket extension

with the height gauge. Hold it in

place for 10 seconds.

See Figure 9.

4.7 Glue the other end of the sleeve

gasket in the groove using the

same procedure.

4.8 Push the draped middle of the sleeve gasket and rotating face

gasket into their grooves. Make sure these gaskets are fully

seated in their grooves. Do not apply adhesive. See Figure 7.

4.9 Repeat these steps for the rotating face gasket again noting the

chamfer location.

4.10 Repeat this procedure for the other seal drive half.

5 Seal Drive Split Joint Gasket and Cap Screw

Installation

5.1 Each seal drive half has split gasket grooves machined into

each joint surface. The split joint gasket can be installed in

either groove so long as the gaskets are located 180° apart

when the seal drive is fully

assembled. See Figure 10.

5.2 Wipe the proper split joint gasket

groove clean with alcohol.

Caution: Consult material safety data

sheets for proper handling of

alcohol.

Advertising