8

1.02 - 1.52 mm

(0.040 - 0.060 inch)

5.3 Put one dot of adhesive near the

outer corner. See Figure 11.

5.4 Put one dot of adhesive near the

inner corner.

5.5 Place the split joint gasket in the

groove and position it as shown in

Figure 12. Hold it in place for 10

seconds. The split joint gaskets

should be positioned flush with

the groove surfaces as indicated.

5.6 Coat a seal drive cap screw

with anti-seize and install it

through the clearance hole until

it protrudes 1.02 to 1.52 mm

(0.040 to 0.60 inch) past the

seal drive joint. See Figure 13.

5.7 Repeat this procedure for the

other seal drive half

.

Figure 11