XL90 Part Numbering System

PREFIX

Selection

Code

Automax Manufacture - Black Epoxy

MB

Automax Manufacture - White Food Grade Epoxy

MW

Accord Manufacture - Black Epoxy

AB

Accord Manufacture - White Food Grade Epoxy

AW

Sereg Manufacture - White Epoxy

SW

Valtek Manufacture - White Epoxy

VW

INPUT MODEL

Selection

Code

Pneumatic Input 3-15 psi

90

Electro-Pneumatic Input 4-20mA

91

General Purpose NT3000

Electro-Pneumatic Input 4-20mA

92

FM/CSA Explosion Proof and Intrins. Safe NT3000

Electro-Pneumatic Input 4-20mA

93

CENELEC EExd (Explosion Proof) NT3000

Electro-Pneumatic Input 4-20mA

94

CENELEC EExia & EExib (Intrinsically Safe) NT3000

INDICATION

Selection

Code

Flat Lens with Green Indicator

1

(Standard)

Ultradome with Green Indicator

U

Cover for top-mounted Namur UltraSwitch

T

(includes UltraSwitch mounting kit)

GAGES

Selection

Code

3 Stainless Steel Gages with Brass Fittings

2

(Standard)

2 Stainless Steel Gage with Brass Fitting

3

(Standard)

3 Stainless Steel Gages

4

2 Stainless Steel Gages

5

No Gages

6

TEMPERATURE

Selection

Code

Standard Temperature (Buna-N soft goods)

7

Extended Temperature (Fluorosilicone soft goods)

8

CAM

Selection

Code

Accord Linear Cam

A

Accord 30, 45, 60 & 90 Degree Linear Cam

B

Accord Linear, Square, Square Root (Damper) Cam

C

Accord 0-60 Degree Cam (Butterfly Valves)

D

Sereg Linear and =% Cam - Diaphragm Actuator

E

Valtek Linear Cam - Piston Actuator

F

Valtek =% Cam-Piston Actuator-Rotary Valve

G

CONDUIT THREAD CONNECTION

Selection

Code

1/2" NPT (Standard)

P

M20 Threads

R

OPTIONS - As Needed (See notes 1-4 below)

ANALOG OUTPUTS

Selection

Code

4-20mA Transmitter

F

or

INTERNAL LIMIT SWITCHES

2-SPDT Mechanical Switches with High Resolution Cams

J

2-SPDT Mechanical Switches

K

2-SPST Proximity Switches

M

2-SPDT Proximity Switches

N

2-Intrinsically Safe Solid State Proximity Switches

Q

Conduit

Input

Temp-

Thread

Prefix

Model Indication

Gages

erature

Cam

Connection Option

■■

■ ■

■■

■ ■

■ ■

■ ■

■ ■

■ ■

■ ■

48-12

Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611

Notes:

1. Internal limit switches and an internal transmitter cannot be used simultaneously.
2. When options F, J, K, M, or N are used with an I/P transducer, input model number 91 must be used.
3. When option Q is used with an I/P transducer, input model numbers 90 or 92 must be used.
4. Internal limit switches or an internal transmitter cannot be used in an explosion proof environment. As an alternative, the explosion proof UltraSwitch may be mounted on

top of the positioner. (Use option T.)

5. Namur shaft end connections are standard for Automax and Accord positioners, Double “D” shaft end connections are standard for Sereg and Valtek positioners. Contact

factory for exceptions to this standard.