Flowserve Logix 1200e LGAIM0044 User Manual

General information

Advertising
background image

Valtek SKU 138430

44-1

Valtek Logix 1200e/1210e
Digital Positioner

GENERAL INFORMATION

The following instructions are designed to assist in
unpacking, installing and performing maintenance as

required on Valtek

®

Logix

®

1200e digital positioners.

Series 1000 is the term used for all the positioners
herein; however, specific numbers indicate features

specific to a model (i.e. Logix 1200e indicates that the
positioner uses HART

®

protocol). Product users and

maintenance personnel should thoroughly review this
bulletin prior to installing, operating, or performing any

maintenance on the valve.

Separate Valtek Flow Control Products Installation,
Operation, Maintenance instructions cover the valve

(such as IOM 1 or IOM 27) and actuator (such as IOM
2 or IOM 31) portions of the system and other acces-

sories. Refer to the appropriate instructions when this
information is needed.

WARNING: Standard industry safety practices
must be adhered to when working on this or any
process control product. Specifically, personal
protective and lifting devices must be used as war-
ranted.

Valve and Instrumentation Storage
Procedures

Storage

Control valve packages (a control valve and its instru-
mentation) can be safely stored in an enclosed build-
ing that affords environmental protection; heating is
not required. Control valve packages must be stored
on suitable skids, not directly on the floor. The storage
location must also be free from flooding, dust, dirt, etc.

Pre-installation Inspection

If a valve control package has been stored for more
than one year, inspect one actuator by disassembling
it per the appropriate Installation, Operation, and
Maintenance Instructions
(IOM) prior to valve installa-
tion. If O-rings are out-of-round, deteriorated, or both,
they must be replaced and the actuator rebuilt. All
actuators must then be disassembled and inspected. If
the actuator O-rings are replaced, complete the follow-
ing steps:

1. Replace the pressure-balanced plug O-rings.

2. Inspect the solenoid and positioner soft goods and

replace as necessary.

WARNING: To avoid possible injury to person-
nel or damage to valve parts, users must
strictly adhere to WARNING and CAUTION
notes. Modifying this product, substituting
non-factory or inferior parts, or using mainte-
nance procedures other than outlined could
drastically affect performance and be hazard-
ous to personnel and equipment, and may
void existing warranties.