7. Place new molded filter element into the chamber

cover vent piece. This element provides part of the

track to secure the O-ring installed in the last step.

8. Place spool valve shroud onto spool valve cover.

9. Place the spool valve cover assembly in place by

setting it on the ramp and sliding it until the tab seats

in the slot (Figure 11) and secure with No. 8-32

screw.

Main PCB Assembly

The main PCB assembly contains the circuit board
and processor that perform control functions of the
positioner. The board is encapsulated in a tray with a
protective silicon coating. This module can be easily
replaced if necessary. None of the components inside
the tray are serviceable. This module is to be replaced
as a unit.

Replacing Main PCB Assembly (Figure 12)

1. Make sure valve is bypassed or in a safe condition.

2. Disconnect the power and air supply to the unit.

3. Remove the main cover and disconnect the ribbon

cable from the collector board.

CAUTION: To avoid damaging any components,
exercise caution by gently raising the locking
tab to release the ribbon cable.

4. Remove the PCB assembly by removing the three

No. 6-32 screws and lifting the tray out of housing.

5. Place the new PCB assembly on the bosses inside

the positioner housing.

6. Insert three No. 6-32 screws through the tray into

the threaded bosses and tighten evenly, using a
phillips screwdriver. Do not overtighten.

7. Reconnect the ribbon cable to the collector board

Figure 11: Spool Valve Cover Assembly

Figure 12: Main PCB Assembly

Ribbon Cable

Screws (3)

Main PCB
Assembly

Screw

Spool Valve Cover

Advertising