LRG 16-40, LRG 17-40

– continued –

The standard conductivity-/temperature curves can be adjusted using the operating & display devices

SPECTORcontrol and URB.

Standard curve

Conditioning agent

Basic conductivity at 25°C

1

NaOH (caustic soda)

60 μS/cm

2

NaOH (caustic soda)

080 μS/cm

3

NaOH (caustic soda)

5400 μS/cm

4

NaOH (caustic soda)

000 μS/cm

5

Na

3

PO

4

(trisodiumphosphate)

90 μS/cm

6

Na

3

PO

4

(trisodiumphosphate)

00 μS/cm

7

Na

3

PO

4

(trisodiumphosphate)

5900 μS/cm

8

Na

3

PO

4

(trisodiumphosphate)

00 μS/cm

9

Na



SO

3

(sodium sulfite)

980 μS/cm

10

Dipolique 444

00 μS/cm

11

Levoxin

95 μS/cm

Technical Data

– continued –

Corrosion resistance

Sizing

The electrode body must not be subjected to sharp increases/decreases in pressure. The dimensional

allowances for corrosion reflect the latest state of technology.

If the conductivity electrode LRG x-40 is used for its intended purpose, its safety is not impaired by

corrosion.