2.2 Connection With Valve and Mounting Kit

The LHS actuator is usually supplied with the spool piece already assembled. To assemble the actuator onto the

valve, perform the following steps:

2.2.1 Check the mounting surfaces, the stem adaptor and the spool piece to

assure the proper fit. Clean the flange of the valve and spool piece to

remove oils and greases since the torque is transmitted by friction. Also

remove any rust that may have occurred during the storage.

2.2.2 Secure the valve in the closed/open position, if possible, with the stem

vertical. Lubricate the valve stem in order to ease the assembly. Place the

stem adaptor on the valve stem.

2.2.3 Lift the actuator by specific lift points (eyebolts), using a proper lifting

system. Position the actuator over the valve and lower to engage the

stem adaptor to the actuator bore. Continue to lower until the spool piece

sits on valve mounting surface. This coupling has to take place without

force and only with the weight of the actuator. The mounting bolts (or

studs) of the valve should easily fit into the bolt holes of the spool piece

without any binding. If needed, turn or stroke the actuator a few degrees

and/or adjust the actuator travel-stops.

2.2.4 The mounting nuts (or bolts) connecting the base of the spool piece to the

valve flange must be evenly tightened according to specific tables, available

upon request to Flowserve After Sales Department.

NOTE: In some cases, the coupling between valve and actuator can be direct,

without the need of a spool piece. In other cases, Flowserve can provide an

intermediate spool piece or an adapter flange (fitted under the actuator

housing) and a special bushing to be inserted into the yoke bore.

a

WARNING: In case of spool piece (or adapter flange) installation by the client, it is mandatory to refer to the

“Mounting Interface Dimensions” paragraph of Technical Bulletin No. LFENTB0003, or to follow more specific

instructions included in the job documentation supplied along with the actuator. These assembling instructions

include details of prescribed stud bolts and their maximum allowable threaded length, in addition to the Loctite

type to be used for a perfect sealing of Scotch yoke housing.

a

CAUTION: The actuator lifting and handling should be made by qualified staff and in compliance with the laws and