OPERATING HEATER

Continued

MANUAL CONTROL INFRARED

MODELS ONLY

TO SELECT

HEATING LEVEL

WARNING: When running

heater, set control knob at LOW

or HIGH locked positions for

double burner heater or ON po-

sition for single burner heater.

Never set control knob between

locked positions. Poor combus-

tion and higher levels of carbon

monoxide may result.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Slightly press in control knob and turn counter-

clockwise

to the LOW or HIGH positions

for double burner heater or ON position for

single burner heater.
IMPORTANT:

Release downward pressure

while turning control knob. Control knob will

lock at the desired position.
Control Double
Knobs Burners

ON

OFF

PILOT

IGN

OFF

Control Single
Knob Burner

Figure 20 - Burner Patterns

INSPECTING BURNER

Check pilot flame pattern and burner flame pat-

tern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern.

Figure 22 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not touching the

thermocouple. This will cause the thermocouple

to cool. When the thermocouple cools, the heater

will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 22
• turn heater off (see To Turn Off Gas to Appli-

ance, page 14)

• see Troubleshooting, page 18
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

have no yellow or orange color.

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Figure 21 - Correct Pilot Flame Pattern

Figure 22 - Incorrect Pilot Flame Pattern