Troubleshooting – Desa VN600BA User Manual

Page 20

Advertising
background image

www.desatech.com

110720-01J

20

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Heater shuts off in use (ODS

operates)

Slight smoke or odor during initial

operation

Heater produces a whistling noise

when burner is lit

Heater produces a clicking/tick-

ing noise just after burner is lit

or shut off

White powder residue forming

within burner box or on adjacent

walls or furniture

Moisture/condensation noticed

on windows

REMEDY

1. Open window and/or door for

ventilation

2. Contact local natural or pro-

pane/LP gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 17)

1. Problem will stop after a few

hours of operation

1. Turn control knob to LOW or

position 1 and let warm up for

a minute

2. Operate burner until air is

removed from line. Have gas

checked by local natural or

propane/LP gas company

3. Observe minimum installa-

tion clearances (see Figure

4, page 8)

4. Clean burner (see Cleaning

and Maintenance, page 17)

or replace burner orifice

1. This is common with most heat-

ers. If noise is excessive, contact

qualified service person

1. Turn heater off when using

furniture polish, wax, carpet

cleaners or similar products

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

POSSIBLE CAUSE

1. Not enough fresh air is avail-

able

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Residues from manufacturing

processes

1. Turning control knob to HIGH

or position 5 when burner is

cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. Metal expanding while heating

or contracting while cooling

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Not enough combustion/ven-

tilation air

Advertising