Inspecting burner – Desa VN600BA User Manual

Page 16

Advertising
background image

www.desatech.com

110720-01J

16

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

INCORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

INCORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

Figure 23 - Correct Burner Flame Pattern

Yellow
Tipping

Figure 24 - Incorrect Burner Flame

Pattern

(Models VN600A and VP600A will be

lower due to lower input rating)

BURNER FLAME PATTERN
INFRARED MODELS

Figure 25 shows a correct burner flame pattern. Fig-

ure 26 shows an incorrect burner flame pattern.
If burner flame pattern is incorrect, as shown in

Figure 26
• turn heater off (see To Turn Off Gas to Appli-

ance, page 14)

• see Troubleshooting, page 18

Figure 26 - Incorrect Burner Flame

Pattern (Dual Burner Shown)

Figure 25 - Correct Burner Flame Pattern

(Dual Burner Shown)

INSPECTING BURNER

Continued

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide. If burner flame pattern

shows yellow tipping, proceed

with the following instructions.

NOTICE: Do not mistake orange

flames with yellow tipping. Dust

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

BURNER FLAME PATTERN BLUE
FLAME MODELS

Figure 23 shows a correct burner flame pattern.

Figure 24 shows an incorrect burner flame pattern.

The incorrect burner flame pattern shows yellow

tipping of the flame. It also shows the flame higher

than 1/2 the glass panel height.
If burner flame pattern is incorrect, as shown in

Figure 24
• turn heater off (see To Turn Off Gas to Appli-

ance, page 14)

• see Troubleshooting, page 18

Advertising