Flex reading code description, English – Formax 6606 Series User Manual

Page 116

Advertising
background image

An Example of OMR Code

In the figure the legend for the following example is shown. In this example, a set of 8
sheets with one selective feed and three sequence check marks is shown.

• The first position is used for the start mark which must be printed on every sheet.
• The second mark position is used for the insert/accumulate command. A printed

mark means insert, no mark means accumulate. Therefore the mark is printed on
the last sheet of the set.

• Position 3 is reserved for selective feed from the enclosure feeder. Print a mark on

position 3 when a selective feed from the enclosure feeder is required. The marks
are printed on the last sheet of the set.

• Position 4, 5 and 6 are used for the sequence check marks. In this case a three mark

sequence check is used.

Flex Reading Code Description

With "Flex reading" also non-standard codes and alternative document handling algorithms
can be recognized. Flex reading can be activated by a system specific license code and
by a customer specific setting that is saved in a physical dongle.
With Flex three types of reading can be supported:

• OMR
• BCR 1D
• BCR 2D

Depending on the license up to 9 Flex definitions can be used on the system.
Creating a Flex job is similar like creating a OMR / BCR reading job.

112

| Page 112 | feb-24-2014 01:32 | Reading

8

English

Advertising