(4) Bar Codes

Bar code type

Bar dimensions

Readable range

Universal product codes

EAN-13

0.26 to 0.33 mm

0.8 to 1.0 magnifications

(10.24 to 12.99 mils)

EAN-8

0.26 to 0.46 mm

0.8 to 1.4 magnifications

(10.24 to 18.11 mils)

UPC-A

0.26 to 0.33 mm

0.8 to 1.0 magnification

(10.24 to 12.99 mils)

UPC-E

0.26 to 0.56 mm

0.8 to 1.7 magnifications

(10.24 to 22.05 mils)

Interleaved 2of5 (ITF)

2 to 34 digits*

Codabar (NW-7)

3 to 23 digits

Code 39

1 to 17 digits

Code 128 (EAN-128)

1 to 21 digits

* Only even-numbered digits

0.15 mm min.
(5.91 mils)

(5) Multi-line Code Scanning

The BHT-100Q supports multi-line code scanning that can scan up to 3 lines of codes
out of universal product codes, Interleaved 2of5 (ITF), Codabar (NW-7), Code 39, and
Code 128 (EAN-128) at a time in the specified order.

The multi-line code scanning may be specified in user programs only. For details, refer
to the "BHT-BASIC Programmer's Manual (BHT-100 series)."

(6) Optical Properties Required

White cells (white bars):

Reflection intensity

45% min.

Black cells (black bars):

Reflection intensity

25% max.

PCS value

0.45 min.

All of the above values are under the following conditions:

- Ambient illuminance: 500 to 3000 x.

- Light source: Xenon lamp