Options

WARNING! Operating the equipment incorrectly can cause serious damage.
The options described must only be put into operation by trained and quali-
fied personnel. In addition to the safety rules in the operating instructions, the
safety rules of the battery and vehicle manufacturers must also be followed.

Safety

Remote display
option

Operation of the charger via the remote display works in exactly the same way as on
the charger multifunction panel.
Green LED
flashes when charging has terminated correctly
Yellow LED
flashes during charging
Red LED
flashes if an error occurs

Accessing the
Info menu, over-
view

(continued)

Electrolyte circulation menu deactivated

Electrolyte circulation menu activated

Equalisation charging delay time
Only for characteristics with equalisation charging

Aquamatic/end of
charging/cumula-
tive error options

(1)

(2)

X 7/3

X 7/4

N

L

4 A T

X 7/PE

The Aquamatic option incorporates
automatic actuation of a solenoid valve to
automatically fill the battery with water.

The end of charging option is used to
activate a signal lamp. When charging is
complete, the NO contact closes auto-
matically.

The cumulative error option can be used to
activate a signal lamp.
The NO contact closes automatically
whenever a fault (ERROR) is detected,
with the exception of Error 12 „phase
failure“.

(1) Charger
(2) Aquamatic/Charging over/

Collective

fault/

cumulative error options

Fig. 4 Aquamatic/Charging over wiring diagram/

Collective fault/

cumulative error options