LocalNet connec-
tion socket

A standardised 10-pin connection socket is available for the LocalNet option. A remote
display or a relay board can be connected to the LocalNet connection socket.

Option for pro-
tection against
undesired star-
ting

The option for protection against undesired starting can be used to control protective
devices that carry out a specific action if the charger is switched on.

A 1-pin or 2-pin option for protection against undesired starting can be implemented as
required.

Important! While the charger is connected to the mains supply, contacts 1/3 are closed.

Important! While the charger is connected to the mains supply, contacts 1/2 and 4/5
are closed.

Important! The option „Protection against undesired starting - 2-pin with change-over
contact“ MUST NOT be operated on two different circuits.

Fig. 9 Protection against undesired starting 1-pin

wiring diagram

Fig. 10 Protection against undesired starting 2-pin

wiring diagram

1

2

3

(A)

* 50 V / 8 A DC

(A)

1

2

3

4

5

6

* 50 V / 8 A DC

(A) Protection against undesired starting control lines

*

max. contact rating