Cumulative error
floating option

(1)

(2)

X 6/3

X 6/6

4 A T

Fig.5

Cumulative error floating max. 42V
AC/DC/4A

The cumulative error floating option can
be used to control a PLC for example. The
NO contact opens automatically whenever
a fault (ERROR) is detected, including
Error 12 „phase failure“

(1) Charger
(2) Example, connection to PLC

„WARNING!“ Socket/plug X6
is only suitable for protective
low voltage signals of max. 42V
AC/DC/4A. Higher voltages
may lead to destruction of the
device or present an electrical
hazard.

SPS

External stop
option (pilot
contact)

Opening connection X 6/2 and X 6/5
interrupts charging.

(1) Charger
X 6/2 (brown)
X 6/5 (blue)

Fig.6

External stop wiring diagram