Fronius Selectiva Plus (one-phase) User Manual

Page 43

Advertising
background image

13

EN

Charged capacity at the start of re-charging
(Only for characteristics with charging factor control)

Battery capacity
Set the capacity of the battery to be charged

Number of cells
Set the number of cells in the battery to be charged

Electrolyte circulation pump (option)
Activate/deactivate electrolyte circulation pump option

Save settings
Save/do not save settings. Exit Set-up menu

Set-up menu/
service level 2

Start delay time
Set a charging start delay time. Setting interval 10 mins

Electrolyte circulation pump program
Set up electrolyte circulation pump program (for further information
contact customer service).

Charger lead length
Set charger lead length

Charger lead cross-section
Set charger lead cross-section

Important! If you continue to press the INFO button, the charger automatically
switches from service level 2 to service level 1.

Charging factor with activated electrolyte circulation option
Set charging factor with activated electrolyte circulation
(only for characteristics with charging factor control)

Set-up menu/
service level 1

(continued)

Charging factor
Set charging factor

(only for characteristics with charging factor

control)

Error message display
After activation the „Err Nr“ flashes in the display when an error
occurs