Specifications – GAI-Tronics 263-000 Isolation Barrier Unit (I.S. Phone) User Manual

Page 11

Advertising
background image

Pub. 42004-178D

Model 263 Isolation Barrier Unit (IBU)

Page: 11 of 13

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-178d.doc
03/06

Specifications

General/Environmental

Location (Model 263 IBU) ......................................................... Ordinary (non-classified) indoor/outdoor

FCC Registration Number .................................................................................... ADGUSA-65066-TE-E

Ringer Equivalence Number (REN)................................................................................................... 0.4B

IC Certification Number (Canada) .......................................................................................... 822 4541 A

Load number (LN) (Canada)................................................................................................................. 14

Connecting method (Canada)........................................................................................................ CA11A

Operating temperature range............................................................ -40

° F to +140° F (-40° C to +60° C)

Relative humidity .................................................................................. 95% (non-condensing) maximum

Maximum safe wiring distance between IBU and I.S. telephone

Standard wire types ......................................................................................................................... 1 mile

Using GTC 60059-001 conductor ............................................................................................... 1.5 miles

Using GTC 60021-301 conductor ............................................................................................... 1.5 miles

Wiring

Construction.......................................................................................................................... Twisted pair

*Type.......................................................................................................................................... Shielded

Conductor size (minimum) ......................................................................................................... 24 AWG

Wiring loop resistance (maximum) ............................................................................................ 275 ohms

Wiring capacitance (maximum) .................................................................................................. 0.316 uF

*Shielded cable is required where multiple I.S. telephone wires are routed together.

Approvals

When connected according with Pub. 42004-380, Control Drawing 73242:

North America............................................................................... Div. 1, Class I, Groups A, B, C, and D;

Class II, Groups E, F, and G; Class III;

Div. 2 (same Classes and Groups as Div. 1)

Advertising