GAI-Tronics 476-002 Centra-Page Flush-Mount Station User Manual

Confidentiality notice, Introduction, General information

Advertising
background image

Pub. 42004-216B

GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA

610-777-1374

„ 800-492-1212 „ Fax: 610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ® C O R P O R A T I O N

A H U B B E L L C O M P A N Y

Model 476-002

Centra-Page Flush-Mount Station

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive
business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics
retains all intellectual property and other rights in or to the information contained herein, and such
information may only be used in connection with the operation of your GAI-Tronics product or system.
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

Introduction

GAI-Tronics Centra-Page systems provide dependable paging and party line communications for rugged
and hazardous industrial facilities. Centra-Page systems feature centrally located electronics that provide
environmental protection and unitized amplification for easy maintenance. Standard Centra-Page cabinets
can support up to 30 handset stations and, in most cases, up to 60 paging speakers. Alarms and telephone
interfacing can also be added to Centra-Page systems.

The Model 476-002 Flush-Mount Station is used for paging and party line communications. When
installed in accordance with a control drawing 72979
, the station provides intrinsically-safe operation
in Class I, Div. 1, Groups C and D hazardous areas.
The station is equipped with a push-to-page
handset and party line selector.

General Information

The Model 476-002 Flush-Mount Station is enclosed in a metallic housing with a front panel measuring 6
H

× 3.5 W inches. See Figure 1 for the dimensions of the wall cutout needed for flush mounting the

station.

Although there is no absolute limit on the number of stations in simultaneous use on a given intercom path
(party line 1 or 2) for a conference-type call, the effectiveness of the sidetone rejection circuit diminishes
and overall performance begins to diminish after four or more stations are connected together. Therefore, it
is recommended that conference-call party line conversations be limited to four simultaneous users.

Advertising
This manual is related to the following products: