1. To generate a page, lift the handset, and check for an available party line.

2. Press the handset pressbar, and announce the page indicating which page line to use. The page is heard

over the system speakers.

3. Release the pressbar and wait for a reply.

4. The paged individual goes to a handset station, uses the page line selector to select the specified party

line, and lifts the handset to reply. Full-duplex communication can then take place.

Specifications

Electrical

Handset:
Microphone .................................................... 10 ohms; pressure differential, noise-canceling dynamic

Receiver ....................................................

150 ohms; high efficiency dynamic, hearing aid compatible

Cable ................................................................................... Retractile, 6 feet (1.82 m) extended PVC

Material .....................................................................................................................

Light gray ABS

Controls ...................................................................................................................

Handset pressbar

Frequency response................................................................................................ 200-2,000 Hz, +/-3 dB

Distortion .......................................... Microphone input to receiver output 2% (nominal line level at 1 kHz

Sidetone rejection................................................................................. 14 dB (nominal line level at 1 kHz)

DC line current ............................................................................................... Each handset: 8 mA typical

Mechanical

Construction/finish............................................................................. Cold-rolled steel/ gray baked enamel

External controls...................................................................................... Rotary party line selector switch

Mounting.................................................................................................................... Flush-mount in wall

Connections .............................................................................. Internal screw-type barrier terminal blocks

Operating temperature range ................................................................ -22º F to +140º F (-30º C to 60º C)

Dimensions:

Front panel .............................................................................. 6 H

× 3.5 W inches (152.4 × 88.9 mm)

Behind panel..................................................................................................... 3.75 inches (95.2 mm)

Cutout ........................................................ 2.5 W

× 4.86 H × 2.5 D inches (63.6 × 123.6 × 63.5 mm)

Shipping weight ................................................................................................................. 6.8 lbs (3.1 kg)

Approvals

NRTL approved for use in US and Canada for the following hazardous locations:

Intrinsically safe for............................................. Class I, Div. 1, Groups C and D hazardous locations

when installed in accordance with Control Drawing No. 72979. Exia

Listed for use in................................................... Class I, Div. 2, Groups C and D hazardous locations

when installed in accordance with Control Drawing No. 72979