Operation, Volume control jumper setting, Specifications – GAI-Tronics 226-002 Div. 2 Industrial Telephons User Manual

Page 13

Advertising
background image

P

UB

.

42004-339F

M

ODEL

226-002,

341-001,

AND

351-001

D

IV

.

2

I

NDUSTRIAL

T

ELEPHONES

P

AGE

12 of 14

e:\standard ioms - current release\42004 instr. manuals\42004-339f.doc
07/14

Operation

1. Lift the handset to place a call.

2. The handset receiver volume control, which is located on the handset, can be adjusted to the desired

level by pressing the handset pressbar.
N

OTE

: Pressing the handset pressbar increases the volume in 3 dB increments. The volume starts at

0 dB and increases to a maximum of 18 dB. Pressing the pressbar a seventh time returns the volume
to 0 dB.

3. Dial the desired number. After completion of the call, place the handset on-hook.

Volume Control Jumper Setting

The handset receiver volume control is factory-set to default to its original setting (0 dB) when the
telephone is hung up. To save the volume control setting, jumper J4, which is factory-set at positions 2
and 3, must be moved to positions 1 and 2.

Specifications

Electrical (Typical)

Frequency response .............................................................................................................. 300 to 3,000 Hz
Inter-digit pause .................................................................................................................................. 100 ms
Minimum loop current ........................................................................................................................ 20 mA
Operation ....................................................................................................................................... Loop start
Signaling tone (DTMF) ................................................................................................ 100 ms tone duration
Supervisory dc current ............................................................... Minimum 20 mA dc; maximum .60 mA dc
Supervisory dc voltage ................................................................ 24 V dc to 60 V dc (not polarity sensitive)
Network interface ........................................................................................................................... Loop start
Minimum loop center .......................................................................................................................... 20 mA
Network signaling ............................................................................................................................... DTMF

Environmental

Operating temperature ......................................................................... −40º F to +140º F (−40º C to +60º C)
Humidity ...................................................................................................................... 90% non-condensing

FCC Information

FCC Registration Number .............................................................................. US: ADGTE10A-46048HAC
Ringer Equivalence Number (REN) .............................................................................................. 1.0A/1.3B
Network connection (USOC) ................................................................................................................. RJ11
Meets hearing aid compatibility magnetic field intensity and volume control technical standards per FCC
Sections 68.316 and 68.317.

IC Information (Canada)

IC Certification Number ................................................................................................................ 82211754
Ringer Equivalence Number (REN) .............................................................................................. 1.0A/1.3B
Connecting Method ............................................................................................................................ CA11A