Maintenance

Regular inspection and a good preventive maintenance program will increase the reliability of your
GAI-Tronics station. The GAI-Tronics Field Service Department can formulate a service contract suited
to your facility’s specific need for preventive maintenance. In addition, the following procedure can be
used to keep Page/Party

®

systems operating effectively.

WARNING

Before performing any of the following preventive maintenance steps, remove

all power from the station.

1. Remove the amplifier from the enclosure.

2. Visually check the interior of the enclosure for signs of contamination such as dust, condensation or

process liquid.

3. Using the No. 10440-002 Maintenance Cable, plug the amplifier into the connector in the enclosure.

Check, and if necessary, adjust the amplifier to maximize performance.

4. Reinstall the amplifier in the enclosure. Ensure that all gaskets and hardware are in place. Failure to

install the gaskets, which also act as spacers, can result in damage to the connectors on the amplifiers
and inside the enclosures and can cause system faults.

It may become necessary to re-terminate some or all of the enclosures in a system. If so, strip the wires
back to clean copper and connect only one wire to each connector to allow for easier future
troubleshooting.

If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#). Equipment should be shipped prepaid to GAI-Tronics with the return authorization number and a
purchase order number. If the equipment is under warranty, repairs will be made without charge. Please
include a written explanation of all defects to assist our technicians in their troubleshooting efforts. Call
800-492-1212 for help in identifying the Regional Service Center closest to you.

Troubleshooting

The following table lists some hints to aid technicians in troubleshooting.

Problem Solution

Feedback
occurs only
during page.

1. If a speaker is close to the station, try using the muting feature in the amplifier

enclosure at the terminal blocks. Connect the violet wire at TB1-8 to TB1-7.
Refer to the wiring diagram.

2. Ensure that speakers attached to other stations located nearby are not pointed in

your direction. If changing the orientation of the other speakers has no effect,
mutual muting may be required. Mutual muting silences all the speakers within
proximity to the affected stations during a page from any one of the mutually
muted stations. Connect the orange wire (spare) to the TB1-7 of all the stations to
be mutually muted. N

OTE

: If too many stations are selected, paging coverage can

be adversely affected.

3. Check line terminations at the line balance assembly. Line balance assembly

connections are critical.

Crosstalk
occurs.

One or more system cable pairs may be improperly terminated. Visually inspect the
system cable connections for accidental crossing of the cable pairs or grounds.