GAI-Tronics ICS Page/Part Weatherproof Handset/Speaker Amplifier Station User Manual

Ics weatherproof page/party, Station quick installation guide

Advertising
background image

Pub. 42004-718L2HQG

GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA

610-777-1374

 800-492-1212  Fax: 610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ® C O R P O R A T I O N

A H U B B E L L C O M P A N Y

ICS Weatherproof Page/Party

®

Station Quick Installation Guide

Important Safety Instructions

1. Read, follow, and retain instructions – All safety and operating instructions should be read and followed before operating the unit.

Retain instructions for future reference.

2. Heed warnings – Adhere to all warnings on the unit and in the operating instructions.

3. Attachments – Attachments not recommended by the product manufacturer should not be used, as they may cause hazards.

4. Servicing – Do not attempt to service this unit by yourself. Opening or removing covers may expose you to dangerous voltage or

other hazards. Refer all servicing to qualified service personnel.

5. This permanently connected apparatus must have a UL Listed 15-amp circuit breaker incorporated in the electrical installation of

the building.

General Information and Available Options

This

guide covers the installation of the ICS Weatherproof Page/Party

®

Station. Figure 1 shows configurations with the following

options:

Universal ac or 24 V
dc power

Single or multi-party
system, or amplifier
only

All Call

SmartSeries

Alternate page
destination

Emergency party
line (EPL)

Auxiliary jack

VLC

RTU

All ICS Stations are wired in parallel. Good system layout design minimizes the cable required. Refer to Pub. 42004-718L2 at the
“Manuals & Specs” link at

www.gai-tronics.com

for detailed explanations of the available configuration options and adjustments,

system design information, and warranty.

Mounting and Wiring

Mount the enclosure using the four 0.437-inch (11 mm) diameter holes located on the mounting flanges with 3/8-inch (M8) hardware.

Remove front panel and drill or punch wire entry openings in the rear enclosure. See Figure 2 for suggested locations. There must be
a minimum of ½ inch (12.7 mm) of material between wire entry holes. The recommended entry is via the enclosure bottom to prevent
moisture from dripping onto the terminals. Top entry is not permitted, as the power supply is located at the top of the enclosure.
Basic wiring connections are shown on Figure 3. Use GAI-Tronics 60029 series multi-party cable or 60038 series single party cable
terminated with #6 spade lugs. Torque the terminal block screws to 8–10 in-lbs (0.90–1.13n-m) when attaching the spade lugs.

Figure 1. ICS Weatherproof Station with available options (AC Version shown)

Advertising