ICS Zone 2/22 Weatherproof Page/Party

®

Station Quick Installation Guide

Important Safety Instructions

This equipment is suitable for use in Zone 2/22 hazardous areas OR non-hazardous locations only. Combinations of equipment in your system are subject to
investigation by the local Authority Having Jurisdiction at the time of installation.

Read, follow, and retain instructions – All safety and operating instructions should be read and followed before operating the unit. Retain instructions for future
reference.
Heed warnings – Adhere to all warnings on the unit and in the operating instructions.
Attachments – Attachments not recommended by the product manufacturer should not be used, as they may cause hazards. Maximum system cable length is not to
exceed two miles.
Servicing – Do not attempt to service this unit by yourself. Opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to
qualified service personnel.

WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – Model 10401-201 Headset and 10416-103 Extension Cord should be used in Group IIB or
Group IIA areas only.

Capacitance values of 140 pF to 580 pF were measured on the external metallic unearthed components of this equipment. As such, special care must be taken in
installation location and environment to address this hazard. See EN TR50404, “Electrostatics – Code of practice for avoidance of hazards due to static electricity” for
additional information in regards to proper installation and potential hazards.

WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.
Avertissement – Risque d’explosion – Avant de débrancher l'équipement, couper le courant ou assurer que le secteur est su pour n'être pas hasardeux.

WARNING

In 24 V dc systems: Under NO condition should this equipment be operated from a battery charger without the batteries connected.

In 24 V dc systems, most chargers have an unloaded output of 35 to 45 volts that can quickly damage the equipment designed for nominal 24 volts. The maximum
battery voltage should never exceed the maximum specified input voltage.

General Information and Available Options

This guide covers the installation of the ICS Zone 2/22 Weatherproof Page/Party

®

Station. Figure 1 shows configurations with the following options:

Universal ac or 24 V dc power

Auxiliary jack

VLC

RTU

Emergency party line (EPL)

Single party system

Alternate page

SmartSeries

Amplifier only

All Zone 2/22 ICS Stations are wired in parallel. Good system layout design minimizes the cable required. Refer to Pub. 42004-734L2 at the
“Manuals & Specs” link at

www.gai-tronics.com

for detailed explanations of the available configuration options and adjustments, system design

information, and warranty.

Mounting and Wiring

Mount the enclosure using the four 0.31-inch (8 mm) diameter holes located on the mounting flanges with 5/16-inch (M6) hardware.

Remove front panel and drill or punch wire entry openings in the rear enclosure, or gland plate when present. See Figure 2 for suggested locations.
There must be a minimum of ½ inch (12.7 mm) of material between wire entry holes. The recommended entry is via the enclosure bottom to prevent
moisture from dripping onto the terminals. Top entry is not recommended. Basic wiring connections are shown on Figure 3. Use GAI-Tronics
60029 Series multi-party cable or 60038 Series single party cable terminated with #6 spade lugs. Torque the terminal block screws to 8–10 in-lbs.
(0.90–1.13 n-m) when attaching the spade lugs.

Ensure any unused openings are sealed with proper fittings per local standards. All metric cable entry devices and blanking elements shall be
certified for Zone 2/22 applications with an IP66 rating, suitable for conditions of use and correctly installed. Use field wiring suitable for the
ambient temperature.

Figure 1. ICS Zone 2/22 Weatherproof Station (AC Version) with available options