Connections to the merge/isolate cabinet – GAI-Tronics MS05-101 Desktop Master Station consisting of Subset, Amplifier and Enclosure User Manual

Page 3

Advertising
background image

Pub. MS05-101iom.2

Model MS05-101 Desktop Master Station

Page:

3 of 11

\\86h27g1-fs\iomdocs\opnotes -- released\mi05-00x merge-isolate cabs\ms05-101.dir\ms05-101iom2.doc
03/09

Connections to the Merge/Isolate Cabinet

1. Locate the Termination PCBA in the lower left corner of the merge/isolate cabinet.

2. Connect the master station cable to TB6 in the cabinet. Refer to the Wiring Terminations Table.

A 9-pair cable (No. 18–20 AWG) is recommended for this connection.

Wiring Terminations Table

Terminals

Master Station

Merge/Isolate Cabinet

Function

TB3-23 and TB3-24

TB6-1 and TB6-2

RS-485 data line (+ /-)

TB3-25

TB6-3

Data ground

TB1-10 and TB1-11

TB6-5 and TB6-6

Page monitor (See note.)

TB1-8 and TB1-9

TB6-7 and TB6-8

Page line (See note.)

TB2-12 and TB2-13

TB6-9and TB6-10

Party Line 1

TB2-14 and TB2-15

TB6-11 and TB6-12

Party Line 2

TB2-16 and TB2-17

TB6-13 and TB6-14

Party Line 3

TB2-18 and TB2-19

TB6-15 and TB6-16

Party Line 4

TB2-20 and TB2-21

TB6-17 and TB6-18

Party Line 5

N

OTE

: If connecting to Model MI05-101 Merge/Isolate Cabinet, jumper the page line (TB1-8 and

TB1-9) to the page monitor line (TB1-10 and TB1-11). If these lines are not tied together, the master
station speaker will not broadcast.