2 of 11, When replacing an existing pvc cord, use a heyco, Figure 1. handset outline diagram – GAI-Tronics 12514-004, 12514-005, 12514-006 Thermoplastic Elastomer Cord Kits User Manual

Page 2

Advertising
background image

Pub. 42003-026C

T

HERMOPLASTIC

E

LASTOMER

C

ORD

R

EPLACEMENT

K

IT

Page:

2 of 11

\\s_eng\gtcproddocs\standard ioms - current release\42003 kit manuals\42003-026c.doc
7/00

3. When replacing an existing PVC cord, use a Heyco

®

bushing tool or a needle nose pliers to squeeze the

notch on the front panel side of the strain relief bushing and pull out the bushing.

4. When replacing a thermoplastic elastomer cord, remove the handset cord fastener clip located on the

back side of the front panel. The fastener clip secures the bushing and the cord to the front panel.

5. Pull the old cord through the front panel and set aside.

6. Remove the lower cap from the handset. Lift out the transmitter and the transmitter cup. Disconnect

both wires.

7. Remove the receiver cap, lift out the receiver and disconnect both wires.

8. Pull the wire harness out of the handset.

YELLOW

BLUE

BLACK

WHITE

GREEN

RED

TRANSMITTER
CAP

WASHER

TRANSMITTER

RECEIVER

CAP

GASKET

RECEIVER

PLASTIC CUP

PRESSBAR

COPPER SPRING

COPPER PLUNGER

Figure 1. Handset Outline Diagram