GAI-Tronics 110438-001 Intrinsically-Safe Microphone Barrier Kit User Manual

Intrinsically-safe microphone barrier kit, Confidentiality notice, General information

Advertising
background image

Pub. 42003-209B

GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA

610-777-1374

„ 800-492-1212 „ Fax: 610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ® C O R P O R A T I O N

A H U B B E L L C O M P A N Y

Intrinsically-Safe Microphone Barrier Kit

Model 10438-001

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.

General Information

The Model 10438-001 Microphone Intrinsically Safe Barrier Kit is designed for utilizing a remote
gooseneck microphone in a Class I, Div. I, Group D hazardous area. The kit provides an intrinsically safe
barrier. This allows the use of the microphone at a location other than the station to which it is connected.
The enclosure, which is approved for Class I, Div. I, Group D areas, must be used in applications where
the microphone is mounted remotely from a station. Examples include the GAI-Tronics Model 400-001
and 400-002NS Rigcom Stations.

The Model 10438-001 Microphone Intrinsically Safe Barrier Kit includes the following components:

Qty Description

1

Gooseneck Microphone Assembly with Mounting Flange

1

Class I, Div. I, Group D Enclosure with I.S. Barrier PCBA

Installation

This enclosure must be installed by trained, qualified and competent personnel. Installation must comply
with state and national regulations, as well as safety practices for this type of equipment.

Model 10438-001 must be installed in accordance with GAI-Tronics Pub. 42004-381, Control Drawing #
73214.

CAUTION

Do not install this equipment in hazardous areas other than those indicated

on the approval listing in the Specifications section. Such installation may cause a safety hazard and
consequent injury or property damage.

WARNING

To reduce the risk of fire or electrical shock, do not expose this apparatus to

rain or moisture.