Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.

General Information

The Model 10438-101 Microphone Intrinsically-Safe Barrier Kit is designed for connection exclusively to
a GAI-Tronics Model 400-003 or 400-004 Rigcom Zone 1 Station in order to utilize a remote gooseneck
microphone in a hazardous area. The kit provides an intrinsically safe barrier. This allows the use of the
microphone at a location other than the station to which it is connected. The enclosure must be used in
applications where the microphone is mounted remotely from a station.

The Model 10438-101 Microphone Intrinsically-Safe Barrier Kit includes the following components:

Qty Description

1

No. 12801-001 Gooseneck Microphone Assembly with Mounting Flange

1

No. 69544-001 Enclosure with I.S. Barrier PCBA

Installation

This enclosure must be installed by trained, qualified and competent personnel. Installation must comply
with state and national regulations, as well as safety practices for this type of equipment.

CAUTION

Where multiple circuits extend from the same piece of associated apparatus, they

must be installed in separate cables or in one cable having suitable insulation in accordance with the
requirements of BS EN 60079-25 / IEC 60079-25.

CAUTION

Do not install this equipment in hazardous areas other than those indicated on the

approval listing in the “Specifications” section. Such installation may cause a safety hazard and
consequent injury or property damage.