Installation, Removing the old pcba assembly, Installing the new pcba – GAI-Tronics 12565-701, 12565-702, 12565-802 VoIP and VoIP WiFi PCBA Replaement Kits User Manual

Page 2

Advertising
background image

Pub. 42003-263B

M

ODEL

12565-701,

-702,

&

-802

V

O

IP

&

V

O

IP

W

I

F

I

T

ELEPHONE

PCBA

R

EPLACEMENT

K

ITS

Page

2 of 16

f:\standard ioms - current release\42003 kit manuals\42003-263b.doc
02/15

Installation

Model 226-700

Removing the Old PCBA Assembly

1. Use the Model 233-001 Security Screwdriver to remove the eight front panel screws and remove the

panel from the enclosure after disconnecting the Cat5 or CatE5 cable from the VoIP Circuit PCBA.

2. Disconnect the handset, hookswitch, volume control push button, keypad, and ringer cables from the

PCBA.

3. Disconnect any optional (input/output) cables from the PCBA.

4. Depress the locking tab on each nylon standoff while lifting up on the corner of the PCBA to remove

it.

Installing the New PCBA

1. Align the holes of the new PCBA with the snap-on nylon standoffs in the telephone, maintaining

proper orientation. Refer to Figure 1 as an example.

2. Press firmly on each corner of the PCBA to lock the standoffs.

3. Reconnect the handset, hookswitch, volume control push button, keypad, and ringer cables to the

PCBA. Refer to Figure 1.

4. Reconnect any optional (input/output) cables from the PCBA.

5. Use the Model 233-001 Security Screwdriver to install the eight front panel screws.

N

OTE

: For Model 226-700 VoIP Telephones purchased prior to December 2013, the ringer assembly and

volume control push button assembly must be replaced for proper operation when the PCBAs in this kit
are replaced.

Advertising