15
Index Control (Slave)
The following describes the Program Variable Selector Switch settings for the GSP motor control
using Gullco’s GSP-2004-7 micro-processor chip (Index Control), as rotated clockwise from zero (0)
top dead center.
Position Details:
0
Normal Operating Position - The control needs to be in this position to allow normal
operation of the unit (top-dead-center).
P.I.1
Index Direction – Programs the direction that the indexing device is to move the
gun/torch for each index. The variable options are either “Forward” (illuminated Forward
Motion Commanded LED) or “Reverse” (extinguished Forward Motion Commanded
LED).
P.I.2
Index Distance - Sets the incremental distance that the indexing device will travel for
each gun/torch index. If the motor control speed display is calibrated in inches per
minute, these parameter values will represent index distance in inches. If the speed
display is calibrated in centimetres per minute, these parameter values will represent
index distance in centimetres. The variable value range is from 0.01 to 9.99, in
increments of 0.01
P.I.3 to
P.I.9
Reserved for future use.
Factory Settings:
The following table shows the settings/values of the Programmable Parameter/Variables as
supplied from the factory:
Switch Position
Parameter
Value
Cycle
Control
(Master)
P. 1
Travel Motion Delay
00.3 (seconds)
P. 2
Arc On/Off During Index
On
P. 3
Crater Fill Delay
00.3 (seconds)
P. 4
Post Weld Delay
01.0 (seconds)
Index
Control
(Slave)
P.I.1 Index
Direction
Forward
P.I.2
Index Distance
0.18” or 0.46cm