45 amp mechanized shielded consumables, 45 amp mechanized shielded consumables -5 – Hypertherm HRT2 User Manual

Page 35

Advertising
background image

OPERATION

Duramax Retrofit Torch

Operator Manual

3-5

220817

Shield

220854

Retaining cap

220941

Nozzle

220857

Swirl ring

220842

Electrode

45

A

220817

Shield

220941

Nozzle

220857

Swirl ring

220842

Electrode

220953

Ohmic-sensing

retaining cap

45

A

45 amp mechanized shielded consumables

45A Shielded

Air flow rate - slpm/scfh

Mild Steel

Hot

177 / 376

Cold

201 / 427

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

0.5

1.5

3.8

250

0.0

9000

128

12500

126

1

9000

128

10800

128

1.5

0.1

9000

130

10200

129

2

0.3

6600

130

7800

129

3

0.4

3850

133

4900

131

4

2200

134

3560

131

6

0.5

1350

137

2050

132

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

Volts

ipm

Volts

26GA

0.02

0.08

400

0.0

350

128

500

128

22GA

350

128

450

128

18GA

0.1

350

129

400

128

16GA

350

130

400

129

14GA

0.06

0.15

250

0.2

270

130

320

129

12GA

0.4

190

133

216

131

10GA

100

134

164

131

3/16

0.5

70

135

108

132

1/4

0.6

48

137

73

132

Advertising
This manual is related to the following products: