40 amp mechanized unshielded consumables, 40 amp mechanized unshielded consumables -12 – Hypertherm HRT2 User Manual

Page 42

Advertising
background image

OPERATION

3-12

Duramax Retrofit Torch

Operator Manual

40 amp mechanized unshielded consumables

• Torch-to-work dis tance for the following cut chart is 1.5 mm (1/16 inch) for all cuts.

220955

Deflector

220854

Retaining cap

220857

Swirl ring

220842

Electrode

220941

Nozzle

45

A

Mild Steel

Arc

Current

Arc

Voltage

Motion

Delay

Material Thickness

Maximum Travel Speeds

Optimum Travel Speeds

Inches

mm

IPM

mm/min

IPM

mm/min

25

125

0

26 GA

0.5

550

13970

353

8966

128

22 GA

0.8

484

12294

315

8001

130

18 GA

1.3

238

6045

155

3937

131

16 GA

1.5

167

4242

109

2769

40

129

0.25

14 GA

1.9

326

8280

212

5385

Stainless

Arc

Current

Arc

Voltage

Motion

Delay

Material Thickness

Maximum Travel Speeds

Optimum Travel Speeds

Inches

mm

IPM

mm/min

IPM

mm/min

25

127

0

26 GA

0.5

561

14249

365

9271

127

22 GA

0.8

453

11506

295

7493

40

123

0.25

18 GA

1.3

500

12700

325

8255

127

16 GA

1.5

367

9322

239

6071

128

14 GA

1.9

220

5588

143

3632

Aluminum

Arc

Current

Arc

Voltage

Motion

Delay

Material Thickness

Maximum Travel Speeds

Optimum Travel Speeds

Inches

mm

IPM

mm/min

IPM

mm/min

25

125

0

1/32

0.8

564

14326

366

9296

127

1/16

1.5

236

5994

153

3886

40

127

0.25

3/32

2.4

261

6629

170

4318

Advertising
This manual is related to the following products: