OPERATION

3-6

Duramax Retrofit Torch

Operator Manual

45A Shielded

Air flow rate - slpm/scfh

Stainless Steel

Hot

177 / 376

Cold

201 / 427

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

0.5

1.5

3.8

250

0.0

9000

130

12500

129

1

9000

130

10800

130

1.5

0.1

9000

130

10200

130

2

0.3

6000

132

8660

131

3

0.4

3100

132

4400

132

4

2000

134

2600

134

6

0.5

900

140

1020

139

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

%

seconds

ipm

Volts

ipm

Volts

26GA

0.02

0.08

400

0.0

350

130

500

129

22GA

350

130

450

129

18GA

0.1

350

130

400

130

16GA

350

130

400

130

14GA

0.06

0.15

250

0.2

250

132

360

131

12GA

0.4

140

132

206

131

10GA

100

133

134

134

3/16 in.

0.5

52

135

58

135

1/4 in.

0.6

30

141

35

140

220817

Shield

220854

Retaining cap

220941

Nozzle

220857

Swirl ring

220842

Electrode

45

A

220817

Shield

220941

Nozzle

220857

Swirl ring

220842

Electrode

220953

Ohmic-sensing

retaining cap

45

A

Advertising