Examine the main contactor

1. Examine the contacts in the main contactor for black or rough surfaces.

2. If you find too much of this condition, replace the main contactor.

Examine the pilot arc relay

1. Remove the cover of the pilot

arc relay.

2. Examine the contacts inside the

relay for black or rough
surfaces.

3. If you find too much of this

condition, replace the pilot arc
relay.

4. Install the cover of the pilot arc

relay.

Be careful that you do not pinch the wires between the cover and the center panel.

Do the coolant flow test

Do the coolant flow test and record the coolant flow rate. You can find the coolant flow rate on the diagnostic screen
on the CNC. For more information, see

Do a check of the coolant flow on page 13.

If the flow rate is below 2.9 L/min (0.75 g/min), do the coolant flow test in

Coolant flow tests in the Maintenance

section of your system’s instruction manual. You may need to service the coolant system or replace the coolant pump
or motor.

The flow alarm turns on when the flow rate is below 2.3 L/min (0.6 g/min). For more information, see

Testing the flow

sensor in the Maintenance section of your system’s instruction manual.

Examine the coolant tank for contamination. If you find any contamination, flush the tank. See

Do a check of the

coolant level and condition on page 11 for instructions.

Make sure that you use the correct Hypertherm coolant (028872) or use water that meets the requirements in

Water

purity requirements in the Installation section of your system’s instruction manual.