Table 2
Item
Number
Quantity
Component
Cumulative number of arc hours
500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500 6,000
428263
1
Torch rebuild and filter kit without coolant*
X
X
X
X
X
X
X
X
X
X
X
X
428264
1
Torch rebuild and filter kit with coolant*
X
X
X
X
X
X
X
X
X
X
X
X
028872
4 – 6
Coolant (in gallons)**
X
X
X
X
X
X
X
X
X
X
X
X
Kit: Electronics***
428270
428272
2
200 V – 240 V
380 V – 600 V
X
X
X
X
X
X
003249
2
Inrush contactor
X
X
X
X
X
220705
1
Quick-disconnect torch receptacle
X
X
X
1
Torch lead
†
X
X
X
006113
1
Coolant check valve
X
X
006077
2
Gas check valve
X
X
027079
6
10-inch fan
X
X
127039
16
6-inch fan
X
X
229235
1
Coolant flow switch
X
X
229345
1
Coolant solenoid valve
X
X
1
Gas lead
†
X
X
1
Pilot arc lead
†
X
X
041802
1
Power board (PCB2)
X
041817
1
Ignition board (PCB IGN)
X
006109
3
Gas solenoid valve
‡
X
228984
2
X
129854
1
High-frequency transformer (T1)
X
005263
8
Gas pressure sensor
X
229213
2
I/O board
X
Chiller coolant pump
040296
040297
1
200 V – 460 V
575 V – 600 V
X
129792
8
Chopper
X