Cut-cycle time

When the cut-cycle is very short, relays operate more frequently. The system also pierces more frequently. Examples of
this type of cycle are when you cut many small holes or make markings for numbers and letters. These types of operations
can cause the following problems:

Increase wear on pilot arc relay contact pads

Increase wear on the starting components, such as the high-frequency transformer and the high-frequency ignition
board

Increase misfires and error codes (020 or 021)

If your cut-cycle is short, you can replace the following components more frequently.

Description

Part number

Pilot arc relay

003149

Contactor (200 V – 240 V)

003218

Contactor (380 V – 600 V)

003233

HPRXD quick-disconnect torch

220706

High-frequency transformer

129854

High-frequency ignition board (PCB)

041817