H601 power supply -3, H601 power supply – Hypertherm H401 Power Supplies User Manual
Page 23
Advertising

SPECIFICATIONS
H401 & H601
Instruction Manual
2-3
5
H601 Power Supply
Maximum OCV (U
0
)
400 VDC
Current Adjustment Range (I
2
)
200 to 750 A
Output Voltage (U
2
)
80 to 200 VDC (235VDC for high current cutting)
60% @ 150 kW, 104° F (40° C)
Duty Cycle Rating (X)
100% @ 120 kW, 104° F (40° C)
Temperature Rating
14° F ( -10° C) to 104° F (40° C)
Power Factor(cos
ϕ
)
0.47
Cooling
Forced Air (Class F)
Input Power (U
1
– Input Voltage; I
1
– Input Current)
036034
200 VAC (U
1
), 3 Phase, 50 Hz, 740 A (I
1
)
036032
400 VAC (U
1
), 3 Phase, 50 Hz, 370 A (I
1
)
036031
480 VAC (U
1
), 3 Phase, 60 Hz, 310 A (I
1
)
036033
600 VAC (U
1
), 3 Phase, 60 Hz, 246 A (I
1
)
Dimensions and Weight
Width
40" (1015 mm)
Maximum Height
53" (1345 mm)
Maximum Depth
50" (1270 mm)
Weight
2250 lbs (1022 kg)
Advertising