Pac500 control cable with h401 or h601 -7 – Hypertherm H401 Power Supplies User Manual

Page 31

Advertising
background image

INSTALLATION

H401 & H601

Instruction Manual

3-7

5

PAC500 Control Cable with H401 or H601

The power supply control cable from the PAC500 console to the H401 or H601 power supply carries signals for the
contactor control relay, and the pilot arc ground. Note: For PAC500L use cable as designated in manual 800460.

Contactor control relay connection
Location: Power supply center wall
White wire #57
Black wire #58

Pilot arc ground connection
Location: +DC output
Red wire #27

Caution:

The power supply contactor (CON) is energized by the control relay (CR1).
Energizing the contactor directly with the plasma console circuitry will result
in damage to the console flow switches due to excessive inrush currents.

PAC500 Control Cable Connections

57

58

Machine Start

1 2 3

E F (ref)

27

Part No.

Length

028009

50 ft (15 m)

128088

150 ft (46 m)

128089

175 ft (53 m)

PAC500

Wire Terminal

2RECP End

Color

End

Connection

Function

2RECP-A

White

57

T-1

Machine Start

2RECP-B

Black

58

T-2

Machine Start

2RECP-C

Red

27

+ DC Output

P.A. Ground

2RECP-D

Green

Gnd

No Connection

Spare

Advertising
This manual is related to the following products: