Parallel power supply connections -8, Warning parallel systems, Parallel power supply connections – Hypertherm H401 Power Supplies User Manual

Page 32: E f (ref)

Advertising
background image

INSTALLATION

3-8

H401 & H601

Instruction Manual

5

WARNING

Parallel Systems

E

LECTRICAL SHOCK CAN KILL

If the power supply is used in parallel with another power supply, or used as a slave unit with
another power supply, both line disconnect switches must be in the OFF position and remain in the
OFF position during installation and maintenance work.

Parallel Power Supply Connections

For increased capacity, power supplies may be connected in parallel. See figures below. This arrangement will also
cause the panel ammeter on power supply #1 to indicate the total arc current produced by both power supplies.
The panel ammeter on power supply #2 will indicate only the part of the arc current produced by power supply #2.

Power Supply 1

Connect the contactor control relays in parallel.

Power Supply 2

57

58

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

H401-Power Supply 2

H601-Power Supply 1

Single 600 Volt 4/0 Cable

Single 600 Volt 4/0 Cable

600 Volt 4/0 Cable Pairs

To

Plasma Console

Negative (-)

To

Water Table

Star Ground

Positive (+)

SHUNT

SHUNT

SHUNT

To

Remote

Current Display

H601-Power Supply 2

H601-Power Supply 1

Single 600 Volt 4/0 Cable

Single 600 Volt 4/0 Cable

600 Volt 4/0 Cable Pairs

To

Plasma Console

Negative (-)

To

Water Table

Star Ground

Positive (+)

SHUNT

To

Remote

Current Displ

SHUNT

SHUNT

SHUNT

E F (ref)