APPENDIX A – SYSTEM GROUNDING

a-4

H401 & H601

Instruction Manual

4

Figure a-2 Alternate Ground Connection Configuration

The preferred cable routing for this configuration is as shown, but it is acceptable to “daisy-chain” the grounds for
the gas console and other equipment to the ignition console.

Plasma Power Supply

(PE)

Power Cord
Ground

Ferrite Choke

Supplementary

Grounding Rod

Gas Console

Other Equipment

receiving power from the
plasma power supply

Work Table

(PE)

(PE)