Operating data for stainless steel -7 – Hypertherm PAC500 Water Injection Plasma Cutting System User Manual

Page 38

Advertising
background image

PAC500

Instruction Manual

4-7

4

OPERATION

Operating Data for Stainless Steel

Material

Thickness

Inches

mm

Nozzle and

Swirl ring

Size

inches

Gas Type and

Flowmeter

Setting

%

Injection

Water Flow

Setting

%

Torch to

Work

Distance

Inches

mm

Arc

Voltage

Setting

Volts

Arc

Current

Setting

Amperes

Travel

Speed

ipm

mm/min

.035

1

1/8

3

125

250

450

11430

.075

2

.120

N

2

30

85

1/8

3

130

250

300

7620

1/8

3

3/16

5

135

260

200

5080

1/4

6

Maximum current for this nozzle is 260 amp.

1/4

6

145

260

150

3810

1/8

3

1/4

6

140

300

200

5080

1/4

6

.166

N

2

45

75

1/4

6

145

350

150

3810

3/8

10

1/4

6

150

380

125

3175

1/2

13 Maximum current for this nozzle is 400 amp.

1/4

6

155

400

100

2540

3/4

19

5/16

8

160

400

50

1270

1

25

3/8

10

165

400

30

760

3/4

19

3/8

10

165

500

75

1905

2

25

.187

N

2

45

75

3/8

10

165

550

60

1525

1-1/2

38

3/8

10

170

580

30

760

2

50 Maximum current for this nozzle is 600 amp.

3/8

10

170

600

20

510

2

50

1/2

13

190

700

25

635

3

75

.220

N

2

70

100

5/8

16

200

750

12

305

Maximum current for this nozzle is 750 amp.

Use the brass tapered retaining cap part no. 020034 above 400 amperes.

When cutting materials greater than 1-1/2 inches (40mm) thick, lower the level of water in the water table to
3 inches (75 mm) below the lower surface of the workpiece. Also de-energize the Water Muffler pump to improve
arc penetration.

For cutting thicker plate refer to the chart Operating Data for High Current Cutting on page 4-10.